What should I do first?
Stop and make the area safe before you investigate. Keep staff and customers away from the curtain, do not stand or reach under a partly raised shutter, and do not keep pressing the button. Repeated attempts can overheat the motor or make a jam worse.
Note what happened: where the curtain stopped, whether you heard a click, hum, bang or grinding, and whether anything changed recently, such as a power cut, a knock from a vehicle or a new member of staff using it. This helps a technician diagnose the fault quickly if you need one.
What can I check on an electric shutter?
- Power to the shop. Are lights and other equipment working? If not, see our power cut guide.
- The isolator. Check the switch near the shutter has not been turned off.
- Fuse or breaker. Check the fused spur and the consumer unit. Reset a tripped breaker once; if it trips again, leave it off and call a technician.
- Remote handset. Try the key switch or wall button instead. If those work, replace the remote's battery.
- Key switch. Use the correct key and hold it fully turned; many shop shutters are hold-to-run and stop as soon as the key is released.
- Obstructions. With the shutter stationary, look for litter, stones, ice or packaging in the guides or under the bottom rail.
- Photocells. Check nothing is blocking the beam and wipe the lenses with a soft dry cloth.
- Thermal cut-out. If the shutter stopped after several cycles in a row, the motor may have overheated. Leave it to cool, often for half an hour or so, then try again.
What can I check on a manual shutter?
- Make sure every lock is fully released, including bottom locks, padlocks and locking bars into the ground.
- In frosty weather, the bottom rail can freeze to the ground and locks can seize. Use a lock de-icer and wait rather than forcing the curtain.
- Check the guides for obstructions, as above.
- On gear-operated shutters, check the crank handle or hand chain is properly engaged.
If the curtain feels much heavier than usual or will not stay up, the springs may have lost tension or broken. Do not try to adjust them; call a technician.
What do common symptoms usually mean?
| Symptom | Possible cause | Safe action |
|---|---|---|
| Nothing happens at all | No power, isolator off, tripped breaker | Check power, isolator and breaker once |
| Remote fails, key switch works | Flat battery or lost pairing | Replace battery; call us if still not working |
| Starts down, then stops or reverses | Photocell or safety edge detecting an obstruction or fault | Clear and clean; call a technician if it continues |
| Stopped after repeated use | Motor thermal cut-out | Leave to cool, then try once |
| Motor hums, curtain does not move | Jam, brake or motor fault | Stop; call a technician |
| Stops short of the top or bottom | Limit settings drifted or obstruction | Check guides; call a technician to reset limits |
| Curtain lower on one side | Damaged lath, end lock or guide | Stop; call a technician |
When must I stop and call a technician?
Stop using the shutter, keep people clear and, if it is safe to reach, switch off the isolator if you see or hear any of these:
- bent, split or missing laths;
- the curtain riding out of a guide;
- grinding, banging or clunking from the box;
- smoke or a burning smell;
- the shutter dropping, running down on its own or failing to hold its position;
- a loud bang from a manual shutter, which can mean a broken spring;
- a loose box, bracket or guide;
- damaged cables, or water inside the controls.
Our shutter repairs start with a diagnostic visit.
Why should I not touch the springs, barrel or motor?
Shutter springs are wound under high tension and store a lot of energy. If they are released suddenly, parts can spin or strike with enough force to cause serious injury. The barrel and curtain are heavy and can drop without warning if supports are removed. Motors and controls run at mains voltage.
Technicians make a shutter safe before working on it, by isolating the power, supporting the curtain and controlling stored spring energy. That needs training and the right tools. Never open the box, adjust springs, reset motor limits or work under a raised curtain yourself.
What happens on a repair visit, and what does it cost?
A technician makes the shutter safe, finds the cause and explains what is needed before doing further work. Guide prices, excluding VAT, are:
- diagnostic repair visit from £125;
- typical repairs £145–£495, such as replacing damaged laths, realigning guides, fixing safety devices or replacing controls;
- motor replacement £395–£895.
If the shutter is beyond economic repair, we will say so and quote for a replacement.
How can I reduce the chance of another breakdown?
- Keep the guides and the ground under the bottom rail clear.
- Ask staff to watch the curtain while it moves and never to hang from it, ride it or force it.
- Avoid running an electric shutter up and down repeatedly in a short time.
- Keep photocells clean and report new noises early.
- Have the shutter serviced at least once a year, or more often if it is heavily used.
Most breakdowns give some warning, such as a curtain that runs slower than usual, sits unevenly or starts to rattle. Treat those signs as a reason to book a check rather than waiting for the shutter to stop at the worst possible moment.
What should I tell the technician when I call?
A clear description helps the technician arrive with the right parts and can shorten the visit. Have this ready:
- the shop address and the opening affected, for example front, rear or a window;
- whether the shutter is electric or manual, and how it is controlled;
- where the curtain is now: fully open, fully closed or stuck part-way;
- what happened and what you heard, smelled or saw;
- what you have already checked, such as the breaker or the remote batteries;
- whether the shop can be secured, or is open to the street;
- any label on the motor, box or controls, and photos or a short video of the problem.
If the curtain is part-way up, tell us whether people can still pass underneath, and keep the area cordoned off until the technician arrives.
Questions about this guide
Why does my shutter come down a little and then go back up?
That is usually a safety device doing its job. A photocell or safety edge has detected something, or thinks it has. Check for obstructions and clean the photocell lenses. If it keeps happening with nothing in the way, the safety edge, its cable or the photocell alignment may be faulty and should be checked by a technician.
Can I reset the motor limits myself?
We advise against it. Limit adjustment means working on the motor, often at height, and a wrong setting can drive the curtain into the box or the ground and damage it. After any adjustment, the safety devices and forces should be checked. A technician can reset the limits and test the shutter properly.
The shutter is stuck open. Can I leave the shop unsecured overnight?
Avoid it if you can. Arrange a repair as soon as possible, consider temporary measures such as boarding, and tell your insurer or broker, because many policies require security devices to be used when the shop is closed. Do not try to force the curtain down, as that can cause more damage or injury.
Is it safe to keep using a shutter that has started making a noise?
A new noise is an early warning. Grinding, banging or clunking means stop and call a technician. A light squeak may only need attention at the next service, but it is still worth getting checked, because worn bearings or dry guides can lead to bigger failures if left.
Sources
- Maintenance of work equipment (HSE)
- Powered gates: the basics (HSE)
- Workplace (Health, Safety and Welfare) Regulations 1992, regulation 18
This guide is general information, not legal advice. Your local planning authority, landlord and insurer have the final say on your premises.